Serving the electrical utility
industry since 1920

Catalog Numbers and Ratings

To properly configure a complete sensor application, you must specify the catalog numbers for a sensor unit, an output unit, an enclosure and power source and a communication cable. Consult the factory for guidance if assistance is needed to correctly specify the system components.

   
Sensor Unit – Current Only  
   
Voltage

Catalog Number

Wght, Lbs

Nom BIL
kV kV 600 Amp 1200 Amp 2000 amp
7.5 95 CS-0095-0600 CS-0095-1200 CS-0095-2000 30
15 110 CS-0110-0600 CS-0110-1200 CS-0110-2000 32
23 150 CS-0150-0600 CS-0150-1200 CS-0150-2000 34
34.5 200 CS-0200-0600 CS-0200-1200 CS-0200-2000 37
46 250 CS-0250-0600 CS-0250-1200 CS-0250-2000 40
69 350 CS-0350-0600 CS-0350-1200 CS-0350-2000 44
115 550 CS-0550-0600 CS-0550-1200 CS-0550-2000 54
138 650 CS-0650-0600 CS-0650-1200 CS-0650-2000 59
161 750 CS-0750-0600 CS-0750-1200 CS-0750-2000 64
230 900 CS-0900-0600 CS-0900-1200 CS-0900-2000 75
230 1050 CS-1050-0600 CS-1050-1200 CS-1050-2000 80
345 1300 CS-1300-0600 CS-1300-1200 CS-1300-2000 139
500 1470 CS-1470-0600 CS-1470-1200 CS-1470-2000 156
 
   
Specify the catalog number that corresponds to your BIL and continuous current requirements
 

Output Unit

 

Output Signal

Catalog Number

Base

O1 O2 O3
0-.5A/0-1A CO-001 -XX -XX -XX
0-10 VAC VO-010 -XX -XX -XX
To complete the Output Unit catalog number, add the required value to each of the three output signal fields of the base catalog number.  If no output signal is required for the second or third fields use “00” for null value.  For the current outputs use values “.5” (0-.5A) or “01” (0-1A).  For the voltage output use “01” (1.44 VA).

The Output Unit can be provided in several different configurations based on the requirements of customer’s specific application:

Output Signal Formats – Output signals are available with standard formats of   0-.5 amp, 0-1 amp and 0-10 VAC (1.44 VA).  Standard burden resistance is 0-2 ohms.  Other formats may be supported.  Please contact the factory if your device requirements are other than the standard formats presented here.

Inputs/Outputs – The Output Unit accepts up to three current inputs and provides up to three analog outputs.  This allows a single Output Unit to support up to three Sensor Units of the same or different ratings.  Alternately, the input signal from a single Sensor Unit can be used to provide up to three output signals for three separate load devices (meters, relays, rtu’s, etc.)
 
Enclosure/Power Source  

Enclosure Size

Power Source

Catalog Number

Value Supp. By
Std 024 VDC Customer E1-024-S
048 VDC Customer E1-048-S
125 VDC Customer E1-125-S
120 VAC Customer E1-120-S
Large 024 VDC Customer E1-024-L
024 VDC SEECO E2-024-L
048 VDC Customer E1-048-L
125 VDC Customer E1-125-L
120 VAC Customer E1-120-L
Solar SEECO E4-024-L

Power Source – The Output Unit will operate with customer supplied 24, 48 and 125 VDC or 120 VAC.  An optional SEECO supplied 24 VDC power source complete with batteries, battery charger, and battery testing mechanism can be provided, which requires customer supplied 120 VAC.  A solar power source can also be supplied for geographically remote applications.

Enclosure – The Output Unit can be provided complete with an enclosure.  The standard enclosure is provided for most typical applications and is sized to accommodate the output device, terminal blocks for output signal wiring connections, up to three circular, MS connectors and power source inputs.  A larger enclosure is available and is sized to accommodate the above material plus the optional SEECO supplied 24 VDC or solar power source, or other customer supplied equipment (SEL relays, rtu’s, etc.)

 
Communication Cable  
Catalog Number
Base Length
CAB -XXXX
Note: To complete the Communication Cable catalog number, add the required cable length to the base catalog number.  Add leading zeroes where necessary to create a four digit length value, i.e. a 170 foot linear length would be specified as “CAB-0170”.

Communication from the Sensor Unit to the Output Unit is digital not analog, providing a maximum cable length of up to 4,000 feet.  The cable length can be specified in 10 foot increments.  One cable is required per Sensor.

The cable has a UV protected black PVC jacket, which is sunlight resistant, impervious to moisture and vapor penetration and is suitable for installation in both wet and dry locations.  Each end of the cable is pre-terminated with a circular MS connector for quick and easy connection to both the Sensor and Output Unit devices.  Cable is suitable for direct burial.